Product Details
Home> Product Details

PO-E04(F)(SILVER)

PO-E04(F)(SILVER)
  • Details

Piezoelectric Pilot Ignition Mode /Pulser Ignition/Button type
Infrared , Fast Heating , Energy Saving
Flame-Failure Protection Device
3 Ceramic Plates, Three Power Setting
Power Setting : From 1.5kw To 4.1kw
Castors For Easy Moving
Space For Gas Cylinder Up To 15kg
With ODS (Oxygen Depletion Sensor), Anti-tilt device Optional
Build-in electrical heating and fan
900W/1800W, 220V-240V/50HZ
Gas Pressure: 28mbar/37mbar/50mbar
Gas Consumption: Max.298g/h Min.109g/h
Product size: 730×420×352mm 
Packing Dimension: 755×455×385mm
Loadage: 227PCS/20FT 540PCS/40HQ

 

This product is only suitable for well insulated spaces or occasional use.

 

Operating Instructions:

There are 3 controls need to be paid attention .

The first is the valve on the cylinder, which will be used to turn ON and OFF the gas supply.

The second is the gas control knob with a dial which has 3 positions marked on it.

This control knob is located on the top end of the heater (fig 4).

The third is the piezoelectric ignition button next to the gas control knob (fig 4).

Pressing this button will generate a spark on the pilot burner thus igniting the gas to the pilot burner.

 

 

 

Installation

1.      Put the cylinder into the gas heater.

2.      Install the protection baffle to make sure the cylinder cant' move.

3.      Connect the pipe to the gas valve with cap (make sure no leakage).

4.      Connect another side of the pipe to the regulator with cap (make sure no leakage).

5.      Open the gas tap before using the heater, and close the gas tap after using.

 

For electric heating with fan

1)      Operation

a.      Make sure plug is normally earthed. Put plug in the socket.

b.      Press switch “ON/OFF, FAN”to get ready for electric heating and start the fan.

c.      Press switch “900W”to start the electric heating of 900W.

d.      Press switch “900W”to start the electric heating of 900W.

e.      Turn all switch off after use. Remove the plug from the socket.

     As shown in below figure.

 

                            

Table for information requirements for electric local space heaters

P

Model identifier(s): PO-E04(F)

Item

Symbol

Value

Unit

Item

Unit

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

Pnom

1,8

kW

Manual heat charge control with integrated thermostat

[no]

Minimum heat output (indicative)

Pmin

0,9

kW

Manual heat charge control with room and/or outdoor temperature feedback

[no]

Maximum continuous heat output

Pmax

1,8

kW

Electronic heat charge control with room and/or outdoor temperature feedback

[no]

Auxiliary electricity consumption

Fan assisted heat output

[no]

At nominal heat output

elmax

1,735

kW

Type of heat output/room temperature control (select one)

At minimum heat output

elmin

0,885

kW

Single stage heat output and no room temperature control

[no]

In standby mode

elSB 

N/A

W

Two or more manual stages, no room temperature control

[no]





With mechanic thermostat room temperature control

[yes]





With electronic room temperature control

[no]





Electronic room temperature control plus day timer

[no]





Electronic room temperature control plus week timer

[no]





Other control options (multiple selections possible)





Room temperature control, with presence detection

[no]





Room temperature control, with open window detection

[no]





With distance control option

[no]





With adaptive start control

[no]





With working time limitation

[no]





With black bulb sensor

[no]

Contact details:

Zhongshan Presito Household Appliance Co., Ltd.

No.55, Jianye Road, Nantou Town, Zhongshan City, Guangdong, China

Remark:

For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be worse than the declared value at the nominal heat output of the unit.

The seasonal space heating energy efficiency of all local space heaters except commercial local space heaters, ηs (%)

36









 

 

Cleaning &Maintenance:

●       maintenance and cleaning must be carried out with the gas supply turned

        off and the heater cold. do not attempt to clean the heater while it is in use.

●       your heater should be checked annually by a qualified person for safe

        operation and to detect any faults.

●       if any faults are detected in use, stop using the heater and contact your dealer for advice.

●       periodically clean the exterior and rear cylinder, storage area of your

         heater to remove dust an lint built-up, which may affect operation of the heater.

●       light vacuuming with a soft brush will remove any dust built-up on the

        surfaces of the ceramic elements. do not scrape of knock these elements

        as they may become very fragile with use.

●       do not abrasive products to clean the heater.

●       watch the pilot flame while it is in operation. it should burn steadily,

        if it flickers or is yellow tipped, the heater should be checked for correct operation.

●       if any parts need replacement, they must be replaced only with genuine

         original parts supplied by the manufacturer. the use of incorrect or

        substitute the parts may be dangerous and will void any warranty.

●      Do not use wet rag or sprinkling water on the heater while cleaning. This may cause

        serious problem to the heater. Under the circumstance of normal usage, contact our

        agents to conduct regular  maintenance. Leave the heater at a clean and dry area

when it is not used.  

 

 

Previous
Next

FAX

+86-760-22519080

TEL

+86-760-22519081 / 22519082 / 22519083

ADD

No.18, Shangyi Road, Nantou Town , Zhongshan City, Guangdong Province,China